HAND-HELD ISOTOPE IDENTIFIER
FOR ACCURATE IN-FIELD ANALYSIS
 |
The
rad-ID™ offers public safety and federal
agencies a highly accurate and
reliable in-field tool to detect, identify and quickly classify radiological hazards as to exact
isotope, dose rate and location of
greatest concentration. Over 110 Medical, Industrial and SNM isotopes of significance are included
in the extensive radiation library.
Designed to be rugged and easy to operate, the rad-ID can rapidly provide critical isotope
identification for non-technical users
and extensive analysis for highly trained personnel within
minutes.
When used with gamma detectors such as D-tect
Systems rad-D™ and mini rad-D™, huge
areas can be inspected and protected from
radiological hazards at a low cost. An IrDA and a
BlueTooth® wireless interface allows
uploading of data via email / internet as
well as downloading additional identification criteria to
the search library if required.
Download Data Sheet
(PDF) |
|
URSA
II Universal Radiation Spectrum Analyzer
|
Versatile, Flexible, Portable, Compatible,
Adaptable, Multipurpose, Low-cost
The URSA II has been designed taking into
account comments and requests from our current URSA
customers. It has a full-featured MCA program that
can be used with practically any radiation detector
and can extract any data your detector can supply!
Specific applications include:
-
Bulk sample analysis
-
air sample analysis
-
wipe sample analysis
-
thyroid assay
-
environmental monitoring
-
compliance monitoring
-
nuclear medicine
-
identification of unknown nuclides
-
remote monitoring
-
health physics
-
homeland defense
-
portal monitoring
-
education
|
|
 |
"URSA-II MCA", the all-new
fully, quantitative Windows™-based
URSA-II software package has been designed for ease of use
in a 32-bit Windows™ environment.
Software also includes "URSA-II for PPC"
software to run the URSA-II using a Pocket PC (Jornada,
iPAQ, TDS Recon, etc.) running WindowsCE. Can be installed
on as many computers as you like, with no restrictions and
includes free updates.

Software Includes:
• Full-featured library editor. Standard libraries include
all 497 isotopes listed in the "Kocher's Radioactive Decay
Tables."
• Multi-channel scaling mode, peak search and identify,
quantification based on ROIs or peaks search.
• Dual-channel emulator allows use with gas proportional
or phoswich detectors as a "gross alpha/beta" counter-scaler.
• Sophisticated multiple alarm functions are based on the
overall count rate, individual ROIs, exceeding a specific
rate or an increase in rate over a specific time interval.
Alarms can trigger external devices.
• Provisions are included for acquiring and saving spectra
repeatedly and continuously while unattended. Spectra can
be saved and reloaded to "live" for re-analysis or
additional data accumulation, or loaded as a background
spectrum. Saved spectra can be superimposed on the
"active" spectrum for comparison. Spectrum format is
easily accessible by your spreadsheet program. All reports
can be previewed, printed, or saved as text or rich text
files.
• "ASCII" mode allows control of and data collection from
the URSA-II with user's own software or hardware.
Click an image for a larger view
Minimum System Requirements:
486 computer running Windows 95® or higher. Connects to
controlling computer using a standard RS232 serial port,
or USB using RS232-to-USB adapter. Supports both high and
normal data rates using USB, although, not all computers
may be capable of handling the dataflow.
Specifications:
4096-channels, can also be configured for 256, 512, 1024,
or 2048 channels. Internal bias voltage supply provides
positive high voltage from 0 to 2000V at up to 0.5mA.
Adjustable shaping time, 0.25 to 10 µs. Wide gain range by
utilizing coarse and fine gain controls, achieve gain from
x1 to x250.
Detector Connector:
Two detector inputs. One standard series "C" connector for
detectors where the signal is joined with the high voltage
supply. The other is for detectors having separate
connections for high voltage (SHV connector) and signal
(BNC connector). Active detector input is selected via
software, and can be negative, positive, or pre-shaped
(positive) signal.
External Connector:
External connector provides +5V, +12V, and -12V for
external preamplifiers and two logic signals for notifying
external devices of alarm conditions.
Switches:
Power On/Off, and Fast/Normal charging rates. (Internal
switch located in the battery compartment suppresses
battery-charging circuitry for when non-rechargeable
batteries are being used.)
LED Indicators:
On/Off, External power availability, and fast charge
activation
Power:
External 12VDC power supply, six "AA" NiMH rechargeable
batteries (included) with recharging internally, or six
standard alkaline "AA" batteries.
External 12VDC power jack allows instrument to plug into
vehicle. "Fast Charge" of NiMH batteries can also be
selected.
Size:
157 x 90 x 44 mm (6.186 x 3.558 x 1.718 in.)
Weight:
391 grams (13.8 oz.) without batteries.
Options:
RAP
Scintillation Probes
Specifications subject to change. |
Download Data Sheet (PDF, 154 KB) |
|
ICS-4000 &
ICS-4000e
R
& D 100 Award Winning Technology
Comprised of a multi-channel analyzer coupled to a temperature compensated CdTe
radiation detector the ICS-4000 puts a complete gamma/x-ray
spectroscopy system in the palm of your hand. The high resolution detector
and analysis capability of its 4000 channel multi-channel analyzer make this
instrument the ideal choice for a variety of health physics and nuclear
safeguards applications. The ICS-4000 has adjustable gain, multiple ROIs,
spectrum storage and upload, LCD graphic display, rechargeable batteries
that provide 7 hours of continuous service, AC adapter/charger, and more.
The ICS - 4000 displays recorded spectrum and the radiation field strength
in your choice of units. With its high resolution spectra
and built in isotope identification software, the ICS - 4000 can identify a
wide range of isotopes automatically and simultaneously. Memory is provided
for storage of measurement data. An RS-232 serial port allows upload of
stored measurements to a PC for analysis and archiving. The ICS-4000e
provides the same features and specifications, but incorporates a detachable
detector and extension pole to allow measurements in hard to reach areas.
The ICS-4000
was released in the first quarter of 2001.
RAD-60
- Personal Alarm Dosimeter

The RAD-60 Personal Alarm Dosimeter is designed specifically for
standalone use.
The main functions of the instrument can be set up using the push button
without any reader system. There is, however, data communication capability in
the RAD-60 allowing full configuration of the instrument using special
software and an ADR-1 reader.
Features:
- Individual Personal Alarming Dosimeter
- Digital Display for Integrated Dose or Alternatively Dose Rate
- User Selectable Alarm Levels for both Dose and Dose Rate
- Standard Triple A Battery
- Excellent RF Immunity
Download Acrobat PDF-document
The Traveler
from Gamma Products
 |
The Traveler is
a low background alpha/beta proportional counting system with
automatic sample changer. Both 50 & 100 sample options are
available. |
Key Benefits
- Maximum portability
- Weighing less than 500 lbs.
- Table top unit
|
NaI(Tl) Scintillation
Spectroscopy Systems
|
Click here to learn more about NaI(Tl)
Spectroscopy Systems
|
|